Product Features
Flippable front panel and color touch screen allow convenient access and operation
Dynamic frequency sweep function for determining worst case voltage peaks*
Non linear load mode function makes the simulated loading current more realistic*
Short circuit test mode
Supports external analog control function
V-monitor/I-monitor
Adjustable current slew rate, adjustable CV loop speed
LED load simulation function
Ultra high precision voltage & current measurement
Full protection: OCP, OPP, OTP, over voltage and reverse alarm
OCP/OPP testing function
Maximum power point tracking*
50kHz high-speed CC/CR dynamic mode
Up to 20 units master/slave parallel control
500kHz high-speed voltage and current sampling rate
Timing & discharging measurement for batteries
Front panel USB interface supports data import and export
Smart fan control with lower noise and better for environment
SCPI language and standard rack size make it ideal for ATE System integration
Multi versions to meet the cost performance and different applications
Provides four kinds of basic working mode such as CV/CC/CR/CP, and CV+CC/CV+CR/CR+CC complex operating modes
Auto mode function provides an easy way to do complicated tes
* Only professional Electronic Load units support these functions
Function & Advantage
This series adopts high power density design. 8.1kW is with only 4U height.
This series High Power DC Load is equipped with flippable front panel for 4U, 7U, 10U and 13U height models. Together with a large color touch screen provides simple and fast operation for customer. Real-time update of display input data, status and graphical display makes it more intuitive.
This series High Power DC Load provides four kinds of basic operating mode including CV (constant voltage), CC (constant current), CR (constant resistance), CP (constant power), to satisfy a wide range of test requirements.
This series electronic load supports CV loop response speed setting to FAST, NORMAL or SLOW to satisfy different test requirements. This function may avoid the inaccurate measurement or testing fail caused by the response speed mismatch between the load and the power supply, which is possible to improve test efficiency and reduce costs on the equipments, time and expenses.
This series electronic load can be switched quickly between different values in the same operating mode, including CC dynamic mode, CV dynamic mode, CR dynamic mode and CP dynamic mode, CC/CR high speed dynamic mode up to 50kHz. This function is suitable for transient test of power supply, test of battery protection characteristic and battery pulse charging etc. Dynamic mode test has continuous mode, pulse mode and toggle mode.
This series electronic load supports sine wave loading function which allows to load sine wave, can be used for impedance analysis test of fuel cells.
This series electronic load provides a unique constant current dynamic sweep to use frequency conversion to find out the UUT voltage of worst case. This CC dynamic sweep allows the user to edit two load levels, start frequency, end frequency, step frequency, dwell etc. The sampling rate is up to 500kHz, which make it can simulate different loading conditions for most test requirements.
It can be applied to track the maximum power point of solar panels. Through the maximum power point tracking method, the maximum power point of the solar panel can be dynamically searched all the time, which can maximize the effectiveness of solar panels.
Simulating capacitive loads makes the current draw closer to the real situation. It is mainly applied for simulating capacitive loads turn on and turn off test. It can prevent the power supply from charging the capacitors on the motherboard when the power is turned on suddenly, which will cause the inrush current to trigger the power supply over-current protection and make the power supply fail to start smoothly.
This series electronic load has battery discharge function, and can perform discharge test under CC, CR or CP mode. The DC load can set end volatge or time to stop loading correctly and make sure the battery is not damaged due to over discharge. The user can set stop conditions, whenever met any condition, the load will stop loading and counting automatically. During the test, users can observe battery's voltage, discharging time and already-discharged-capacity.
This mode allows automatically switches among CV, CR, CC and CP modes. It is suitable for lithium ion battery charger testing to get a complete V-I charging curve. This flexible auto mode also enormously improve test efficiency.
This series electronic load provides OCP and OPP modes are mainly applied in over-current and over-power points tests. After the testing the load can automatically judge the test result according to the set specifications. Take OPP testing as example, the OPP provides ramped up power for the load to test the UUT voltage whether has reached trigger voltage level and to judge if the protection is acting normally or not.
The list function allows user to create waveform files to automatically simulate various complicated loading conditions. The list mode has 10 files, by editing operating mode (including CC, CV, CR ,CP, Short and ON/OFF), repeat times, total steps, setting value of each step and step time etc. This function can be applied to the testing of output characteristic and stability for power supply.
This series electronic load provides the user with Master/slave mode, supports parallel connection under different power and same voltage and dynamically synchronized. In Master/slave mode, the user only need to control the master one, the load current will be automatically calculated and downloaded to the slave loads. The Master/slave mode greatly simplifies the operation when increased power is needed.
This series electronic load has analog control interface to control the input voltage and current. The external signal 0 to 10V controls the sinking condition from 0 to full scale. Using the external control mode can simulate arbitrary waveform which is ideal for industrial control requirement. The 0 to 10V analog output signal of V-MON/I-MON terminals represent input to which the terminals belong from 0 to full range. An external voltmeter or oscilloscope can be connected to display input voltage/current change.
Options & Accessories
-
Handles (standard)With fixing screws
-
DC input protective cover (standard)With fixing screws
-
BNC cable (standard)Voltage / current output monitoring
-
USB communication cable(standard)For USB communication
-
RS-232 communication cable (standard)For RS-232 communication
-
Remote voltage sampling cable (standard)One red, one black
-
System bus communication cable (standard)Connect for master-slave communication
-
Power cable (standard)
-
Pads (standard)Applicable in 2U/3U/4U
-
GPIB & LAN card & communication cable (optional)For communication between GPIB and LAN
-
Professional version upgrade software (optional)Upgrade version from advanced to professional
Model Search
Model | Voltage | Current | Power | Voltage Resolution | Current Resolution | Voltage Accuracy | Current Accuracy | Size | |
EL200VDC600W | 200V | 60A | 600W | 0.1mV | 0.1mA | 0.015%+0.015%F.S. | 0.04%+0.04%F.S. | 2U | Inquiry |
EL200VDC1200W | 200V | 130A | 1200W | 0.1mV | 0.1mA | 0.015%+0.015%F.S. | 0.04%+0.04%F.S. | 2U | Inquiry |
EL200VDC1800W | 200V | 190A | 1800W | 0.1mV | 0.1mA | 0.015%+0.015%F.S. | 0.04%+0.04%F.S. | 2U | Inquiry |
EL200VDC2400W | 200V | 260A | 2400W | 0.1mV | 0.5mA | 0.015%+0.015%F.S. | 0.04%+0.04%F.S. | 2U | Inquiry |
EL200VDC3000W | 200V | 320A | 3000W | 0.1mV | 0.5mA | 0.015%+0.015%F.S. | 0.04%+0.04%F.S. | 2U | Inquiry |
EL200VDC3400W | 200V | 370A | 3400W | 0.1mV | 0.5mA | 0.015%+0.015%F.S. | 0.04%+0.04%F.S. | 3U | Inquiry |
EL200VDC4400W | 200V | 480A | 4400W | 0.1mV | 0.5mA | 0.015%+0.015%F.S. | 0.04%+0.04%F.S. | 3U | Inquiry |
EL200VDC5600W | 200V | 610A | 5600W | 0.1mV | 0.5mA | 0.015%+0.015%F.S. | 0.04%+0.04%F.S. | 3U | Inquiry |
EL200VDC6600W | 200V | 720A | 6600W | 0.1mV | 0.5mA | 0.015%+0.015%F.S. | 0.04%+0.04%F.S. | 4U | Inquiry |
EL200VDC8100W | 200V | 720A | 8100W | 0.1mV | 0.5mA | 0.015%+0.015%F.S. | 0.04%+0.04%F.S. | 4U | Inquiry |
EL200VDC8800W | 200V | 960A | 8800W | 0.1mV | 1mA | 0.015%+0.015%F.S. | 0.04%+0.04%F.S. | 7U | Inquiry |
EL200VDC10300W | 200V | 960A | 10300W | 0.1mV | 1mA | 0.015%+0.015%F.S. | 0.04%+0.04%F.S. | 7U | Inquiry |
EL200VDC11000W | 200V | 1200A | 11000W | 0.1mV | 1mA | 0.015%+0.015%F.S. | 0.04%+0.04%F.S. | 7U | Inquiry |
EL200VDC12500W | 200V | 1200A | 12500W | 0.1mV | 1mA | 0.015%+0.015%F.S. | 0.04%+0.04%F.S. | 7U | Inquiry |
EL200VDC13200W | 200V | 1440A | 13200W | 0.1mV | 1mA | 0.015%+0.015%F.S. | 0.04%+0.04%F.S. | 7U | Inquiry |
EL200VDC14700W | 200V | 1440A | 14700W | 0.1mV | 1mA | 0.015%+0.015%F.S. | 0.04%+0.04%F.S. | 7U | Inquiry |
EL200VDC15400W | 200V | 1680A | 15400W | 0.1mV | 2mA | 0.015%+0.015%F.S. | 0.04%+0.04%F.S. | 10U | Inquiry |
EL200VDC16900W | 200V | 1680A | 16900W | 0.1mV | 2mA | 0.015%+0.015%F.S. | 0.04%+0.04%F.S. | 10U | Inquiry |
EL200VDC17600W | 200V | 1920A | 17600W | 0.1mV | 2mA | 0.015%+0.015%F.S. | 0.04%+0.04%F.S. | 10U | Inquiry |
EL200VDC19100W | 200V | 1920A | 19100W | 0.1mV | 2mA | 0.015%+0.015%F.S. | 0.04%+0.04%F.S. | 10U | Inquiry |
EL200VDC19800W | 200V | 2160A | 19800W | 0.1mV | 2mA | 0.015%+0.015%F.S. | 0.04%+0.04%F.S. | 10U | Inquiry |
EL200VDC21300W | 200V | 2160A | 21300W | 0.1mV | 2mA | 0.015%+0.015%F.S. | 0.04%+0.04%F.S. | 10U | Inquiry |
EL200VDC22000W | 200V | 2400A | 22000W | 0.1mV | 4mA | 0.015%+0.015%F.S. | 0.04%+0.04%F.S. | 13U | Inquiry |
EL200VDC23500W | 200V | 2400A | 23500W | 0.1mV | 4mA | 0.015%+0.015%F.S. | 0.04%+0.04%F.S. | 13U | Inquiry |
EL200VDC24200W | 200V | 2640A | 24200W | 0.1mV | 4mA | 0.015%+0.015%F.S. | 0.04%+0.04%F.S. | 13U | Inquiry |
EL200VDC25700W | 200V | 2640A | 25700W | 0.1mV | 4mA | 0.015%+0.015%F.S. | 0.04%+0.04%F.S. | 13U | Inquiry |
EL200VDC26400W | 200V | 2880A | 26400W | 0.1mV | 4mA | 0.015%+0.015%F.S. | 0.04%+0.04%F.S. | 13U | Inquiry |
EL200VDC27900W | 200V | 2880A | 27900W | 0.1mV | 4mA | 0.015%+0.015%F.S. | 0.04%+0.04%F.S. | 13U | Inquiry |
EL600VDC600W | 600V | 40A | 600W | 0.5mV | 0.1mA | 0.015%+0.015%F.S. | 0.04%+0.04%F.S. | 2U | Inquiry |
EL600VDC1200W | 600V | 90A | 1200W | 0.5mV | 0.1mA | 0.015%+0.015%F.S. | 0.04%+0.04%F.S. | 2U | Inquiry |
EL600VDC1800W | 600V | 130A | 1800W | 0.5mV | 0.1mA | 0.015%+0.015%F.S. | 0.04%+0.04%F.S. | 2U | Inquiry |
EL600VDC2400W | 600V | 180A | 2400W | 0.5mV | 0.2mA | 0.015%+0.015%F.S. | 0.04%+0.04%F.S. | 2U | Inquiry |
EL600VDC3000W | 600V | 220A | 3000W | 0.5mV | 0.2mA | 0.015%+0.015%F.S. | 0.04%+0.04%F.S. | 2U | Inquiry |
EL600VDC3400W | 600V | 250A | 3400W | 0.5mV | 0.4mA | 0.015%+0.015%F.S. | 0.04%+0.04%F.S. | 3U | Inquiry |
EL600VDC4400W | 600V | 320A | 4400W | 0.5mV | 0.4mA | 0.015%+0.015%F.S. | 0.04%+0.04%F.S. | 3U | Inquiry |
EL600VDC5600W | 600V | 410A | 5600W | 0.5mV | 0.4mA | 0.015%+0.015%F.S. | 0.04%+0.04%F.S. | 3U | Inquiry |
EL600VDC6600W | 600V | 480A | 6600W | 0.5mV | 0.5mA | 0.015%+0.015%F.S. | 0.04%+0.04%F.S. | 4U | Inquiry |
EL600VDC8100W | 600V | 600A | 8100W | 0.5mV | 0.5mA | 0.015%+0.015%F.S. | 0.04%+0.04%F.S. | 4U | Inquiry |
EL600VDC8800W | 600V | 640A | 8800W | 0.5mV | 0.5mA | 0.015%+0.015%F.S. | 0.04%+0.04%F.S. | 7U | Inquiry |
EL600VDC10300W | 600V | 760A | 10300W | 0.5mV | 0.5mA | 0.015%+0.015%F.S. | 0.04%+0.04%F.S. | 7U | Inquiry |
EL600VDC11000W | 600V | 800A | 11000W | 0.5mV | 1mA | 0.015%+0.015%F.S. | 0.04%+0.04%F.S. | 7U | Inquiry |
EL600VDC12500W | 600V | 920A | 12500W | 0.5mV | 1mA | 0.015%+0.015%F.S. | 0.04%+0.04%F.S. | 7U | Inquiry |
EL600VDC13200W | 600V | 960A | 13200W | 0.5mV | 1mA | 0.015%+0.015%F.S. | 0.04%+0.04%F.S. | 7U | Inquiry |
EL600VDC14700W | 600V | 1080A | 14700W | 0.5mV | 1mA | 0.015%+0.015%F.S. | 0.04%+0.04%F.S. | 7U | Inquiry |
EL600VDC15400W | 600V | 1120A | 15400W | 0.5mV | 1mA | 0.015%+0.015%F.S. | 0.04%+0.04%F.S. | 10U | Inquiry |
EL600VDC16900W | 600V | 1240A | 16900W | 0.5mV | 1mA | 0.015%+0.015%F.S. | 0.04%+0.04%F.S. | 10U | Inquiry |
EL600VDC17600W | 600V | 1280A | 17600W | 0.5mV | 1mA | 0.015%+0.015%F.S. | 0.04%+0.04%F.S. | 10U | Inquiry |
EL600VDC19100W | 600V | 1400A | 19100W | 0.5mV | 1mA | 0.015%+0.015%F.S. | 0.04%+0.04%F.S. | 10U | Inquiry |
EL600VDC19800W | 600V | 1440A | 19800W | 0.5mV | 2mA | 0.015%+0.015%F.S. | 0.04%+0.04%F.S. | 10U | Inquiry |
EL600VDC21300W | 600V | 1560A | 21300W | 0.5mV | 2mA | 0.015%+0.015%F.S. | 0.04%+0.04%F.S. | 10U | Inquiry |
EL600VDC22000W | 600V | 1600A | 22000W | 0.5mV | 2mA | 0.015%+0.015%F.S. | 0.04%+0.04%F.S. | 13U | Inquiry |
EL600VDC23500W | 600V | 1720A | 23500W | 0.5mV | 2mA | 0.015%+0.015%F.S. | 0.04%+0.04%F.S. | 13U | Inquiry |
EL600VDC24200W | 600V | 1760A | 24200W | 0.5mV | 2mA | 0.015%+0.015%F.S. | 0.04%+0.04%F.S. | 13U | Inquiry |
EL600VDC25700W | 600V | 1880A | 25700W | 0.5mV | 2mA | 0.015%+0.015%F.S. | 0.04%+0.04%F.S. | 13U | Inquiry |
EL600VDC26400W | 600V | 1920A | 26400W | 0.5mV | 2mA | 0.015%+0.015%F.S. | 0.04%+0.04%F.S. | 13U | Inquiry |
EL600VDC27900W | 600V | 2040A | 27900W | 0.5mV | 2mA | 0.015%+0.015%F.S. | 0.04%+0.04%F.S. | 13U | Inquiry |
EL1200VDC1200W | 1200V | 45A | 1200W | 1mV | 0.1mA | 0.015%+0.015%F.S. | 0.04%+0.04%F.S. | 2U | Inquiry |
EL1200VDC2400W | 1200V | 90A | 2400W | 1mV | 0.1mA | 0.015%+0.015%F.S. | 0.04%+0.04%F.S. | 2U | Inquiry |
EL1200VDC3400W | 1200V | 125A | 3400W | 1mV | 0.2mA | 0.015%+0.015%F.S. | 0.04%+0.04%F.S. | 3U | Inquiry |
EL1200VDC4400W | 1200V | 160A | 4400W | 1mV | 0.2mA | 0.015%+0.015%F.S. | 0.04%+0.04%F.S. | 3U | Inquiry |
EL1200VDC5600W | 1200V | 205A | 5600W | 1mV | 0.2mA | 0.015%+0.015%F.S. | 0.04%+0.04%F.S. | 3U | Inquiry |
EL1200VDC6600W | 1200V | 240A | 6600W | 1mV | 0.2mA | 0.015%+0.015%F.S. | 0.04%+0.04%F.S. | 4U | Inquiry |
EL1200VDC8100W | 1200V | 300A | 8100W | 1mV | 0.2mA | 0.015%+0.015%F.S. | 0.04%+0.04%F.S. | 4U | Inquiry |
EL1200VDC8800W | 1200V | 320A | 8800W | 1mV | 0.4mA | 0.015%+0.015%F.S. | 0.04%+0.04%F.S. | 7U | Inquiry |
EL1200VDC10300W | 1200V | 380A | 10300W | 1mV | 0.4mA | 0.015%+0.015%F.S. | 0.04%+0.04%F.S. | 7U | Inquiry |
EL1200VDC11000W | 1200V | 400A | 11000W | 1mV | 0.4mA | 0.015%+0.015%F.S. | 0.04%+0.04%F.S. | 7U | Inquiry |
EL1200VDC12500W | 1200V | 460A | 12500W | 1mV | 0.4mA | 0.015%+0.015%F.S. | 0.04%+0.04%F.S. | 7U | Inquiry |
EL1200VDC13200W | 1200V | 480A | 13200W | 1mV | 0.4mA | 0.015%+0.015%F.S. | 0.04%+0.04%F.S. | 7U | Inquiry |
EL1200VDC14700W | 1200V | 540A | 14700W | 1mV | 0.4mA | 0.015%+0.015%F.S. | 0.04%+0.04%F.S. | 7U | Inquiry |
EL1200VDC15400W | 1200V | 560A | 15400W | 1mV | 0.5mA | 0.015%+0.015%F.S. | 0.04%+0.04%F.S. | 10U | Inquiry |
EL1200VDC16900W | 1200V | 620A | 16900W | 1mV | 0.5mA | 0.015%+0.015%F.S. | 0.04%+0.04%F.S. | 10U | Inquiry |
EL1200VDC17600W | 1200V | 640A | 17600W | 1mV | 0.5mA | 0.015%+0.015%F.S. | 0.04%+0.04%F.S. | 10U | Inquiry |
EL1200VDC19100W | 1200V | 700A | 19100W | 1mV | 0.5mA | 0.015%+0.015%F.S. | 0.04%+0.04%F.S. | 10U | Inquiry |
EL1200VDC19800W | 1200V | 720A | 19800W | 1mV | 0.5mA | 0.015%+0.015%F.S. | 0.04%+0.04%F.S. | 10U | Inquiry |
EL1200VDC21300W | 1200V | 780A | 21300W | 1mV | 0.5mA | 0.015%+0.015%F.S. | 0.04%+0.04%F.S. | 10U | Inquiry |
EL1200VDC22000W | 1200V | 800A | 22000W | 1mV | 1mA | 0.015%+0.015%F.S. | 0.04%+0.04%F.S. | 13U | Inquiry |
EL1200VDC23500W | 1200V | 860A | 23500W | 1mV | 1mA | 0.015%+0.015%F.S. | 0.04%+0.04%F.S. | 13U | Inquiry |
EL1200VDC24200W | 1200V | 880A | 24200W | 1mV | 1mA | 0.015%+0.015%F.S. | 0.04%+0.04%F.S. | 13U | Inquiry |
EL1200VDC25700W | 1200V | 940A | 25700W | 1mV | 1mA | 0.015%+0.015%F.S. | 0.04%+0.04%F.S. | 13U | Inquiry |
EL1200VDC26400W | 1200V | 960A | 26400W | 1mV | 1mA | 0.015%+0.015%F.S. | 0.04%+0.04%F.S. | 13U | Inquiry |
EL1200VDC27900W | 1200V | 1020A | 27900W | 1mV | 1mA | 0.015%+0.015%F.S. | 0.04%+0.04%F.S. | 13U | Inquiry |